'

Unser Unternehmen FAMAGA ist kein Hersteller, autorisierter Distributor oder offizieller Vertreter der Marke LABOM in Deutschland. Die auf dieser Website angezeigten privaten Warenzeichen und Artikelnummern sind Eigentum ihrer jeweiligen Inhaber.

LABOM – seite 5

Verkauf jedes Produkts aus dem LABOM Katalog zu guten Preisen

Artikel
Beschreibung
Preis
PRESSURE TRANSMITTER PASCAL Ci4 for diaphragm seal operation, hygienic process connection bottom see data sheet D4-016-2 CI4110 nominal range: 0...4 bar, Turndown max. 100:1, overload limit 10 bar; sensor type piezoresistiv A1056 accuracy: <= 0.10% from adjusted measuring span (Lin./Hys./Rep., up to Turndown <=5:1 no changes) F2 parameterizing: see below -1...+3 bar H21 output signal: 4...20 mA with HART high-resolution graphic display with backlight intuitive 4-button operation, quick access to device data available languages (English, German), default setting English M21.1 Y1 material case: stainless steel mat. no. 1.4301/1.4305 (304/303) 2 material front cover: stainless steel, window non-splittering glass degree of protection: IP 65 / IP 67 T30 electrical connection: circular connector M12 x 1 (4 pin) K1085 design: standard X3 temperature compensation: active temperature compensation ATC marking: stainless steel Tag-plate, fixed with stainless steel wire, marking see below W4022 W2002 CALIBRATION PROTOCOL: with 5 measuring points W2674 EAC-TR certification exemption statement process connection: DL DIAPHRAGM SEAL for food / pharmaceutical / biotechnology design with clamp connection see data sheet D5-026 3 process connection: per DIN 32676 model C (Tri-Clamp) for pipes per ASME BPE, DN 2 1/2" / PN 16 430 hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered L23 T14 temperature, media: -10..+150 °C W4035 ADDITIONAL DESIGN: wetted parts electropolished W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts
Auf Anfrage
Preis anfragen
MZ1100 COMBIBAR PRESSURE MEASURING SYSTEM B64 drawing no.: PD-WV-00178 BOURDON TUBE PRESSURE GAUGE: W2002 CALIBRATION PROTOCOL: with 5 measuring points PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 CV3110 A1 pressure sensor: piezoresistive for gauge pressure 059 nominal range: 0...16 bar, overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F80 measuring range: setting see below lower range value: - 1,000 upper range value: + 4,000 unit: bar H21 output signal: 4...20 mA with HART function module 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) M1 display module: without screw cap closed, without window N10 switching module: without case: hygienic housing design with screw cap material: stainless steel degree of protection: IP 66 T30 electrical connection: circular connector M12x1 (4 pin) K1085 design standard process temperature 0...+125 °C, short term up to +140 °C, 1 h ADDITIONAL DESIGN: stainless steel Tag-plate with stainless steel wire marking see below W4022 W2674 EAC-TR certification exemption statement PRESSURE GAUGE DN 100 ECOnomic for food/pharmaceutical/biotechnology acc. to data sheet D2-028-5 BH52 00 case design: IP 65, process connection bottom A99 nominal range: see below -1 ... 4 bar overload protected: 1.3 times pointer: with micro adjusting device for zero-point correction CUSTOMER'S SPECIFICATION: scale: Zeta logo type plate: Labom documentation: Labom W5124 W2674 EAC-TR certification exemption statement DIAPHRAGM SEAL for food/pharmaceutical/biotechnology see data sheet D5-024-3 DL8 090 design: process connection per INGOLD hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm HY D25 process connection: DN 25, hexagon union nut A/F 46, G 1 1/4" 46 insertion length: h = 46 mm E7 basic body material: stainless steel mat.-no. 1.4435 (316L), wetted part G7 diaphragm material: stainless steel mat.-no. 1.4435 (316L) H2 gasket: per EPDM -FDA A400 connection of meas. instrument directly welded system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered L23 DMB_729 T99 temperature, media: see below +10...+150°C W4035 ADDITIONAL DESIGN: wetted parts electropolished W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts
Auf Anfrage
Preis anfragen
Auf Anfrage
Preis anfragen
Auf Anfrage
Preis anfragen
CV3110 PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 B1 pressure sensor: piezoresistive for absolute pressure 059 nominal range: 0...16 bar abs., overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F10 measuring range: 0...16.00 bar abs. H11 output signal: 4...20 mA, rising characteristic (standard) 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) M1 display module: without screw cap closed, without window N5 switching module: with 2 floating channels, pluggable, electrically isolated at all sides, switching capacity 30 V DC / 0.5 A 0 switching module setting: standard, see below 1. switch contact: switch point: 50 % breaker, hysteresis: 0.1 %, falling, standard 2. switch contact: switch point: 50 % breaker, hysteresis: 0.1 %, falling, standard case: hygienic housing design with screw cap material: stainless steel degree of protection: IP 66 T31 electrical connection: circular connector M 12x1 (8 pin) K1085 design standard DD4 DIAPHRAGM SEAL for food/pharmaceutical/biotechnology DRD-connection acc. to data sheet D5-024-4 100 nominal width/pressure: DN 50 / PN 40 HY hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 µm - diaphragm Ra <= 0.38 µm - weld seam Ra <= 0.76 µm A400 connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) L22 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered operating temperature range -10...+140 °C
Auf Anfrage
Preis anfragen

Die Website enthält nur einen Teil der Katalogartikel der Herstellermarke LABOM.

Wenn Sie den gewünschten Artikel nicht gefunden haben, senden Sie eine Anfrage an die E-Mail [email protected] und wir senden Ihnen sicherlich ein unverbindliches Angebot.

Hier können Sie Produkte anderer Marken kaufen